Description
3000 OUTPUT 3000 W SURGE RATING 6000 W
- Output power (continuous): 3000 W
- Surge rating: 6000 W
- Output frequency: 60 Hz +/- 0.2 Hz
- Output voltage: 120 Vac
- Output wave form: True sine wave
- Optimal efficiency: 93%
- No-load power draw (inverting): 2.5 Adc
- Input DC voltage range: 11 – 15 Vdc
- AC connections: Split phase in / dual out, Dual in / dual out
- Output current: 150 A
- Output voltage: 12 Vdc
- Output voltage range: 10.0 – 15.5 Vdc
- Charge control: 3 stage with manual equalize
- Charge temperature compensation: Remote battery sensor (included)
- Efficiency (full load): > 86%
- AC input power factor: 0.95
- Input current (for 150 A charging): 22 A rms nominal
- Input AC voltage: 120 Vac
- Input AC voltage range: 95 – 140 Vac
- Dead battery charge: > 3 Vdc
- Compatible battery types: Flooded / gel / AGM / Pb-Ca
- Transfer relay rating: 2 legs at 30 A each
- Transfer time (AC to inverter and inverter to AC): 20 ms (typical)
- Optimal operating temperature range: – 4°F to 140°F (- 20°C to 60°C)
- Storage ambient temperature range: – 40°F to 185°F (- 40°C to 85°C)
- Dimensions: 7.9″ H x 11.5″ W x 13.2” L
- Unit weight: 50 lbs.
Warranty Terms: 30 Months
- System control panel Part# 809-0921
- Remote on/off panel Part# 808-9002
- Automatic Generator Start (AGS) Part# 809-0915
- 50’ cable for remote on/off panel Part# 31-6262-00
- 25’ network cable for system control panel Part# 809-0940
- 50’ network cable for system control panel Part# 809-0941
- 75’ network cable for system control panel Part# 809-0942
- CSA/NRTL certified to CSA 107.1; UL458 with marine supplement; FCC *Class A; ABYC